Pyrex High Pressure Gage Glass            
               
General Application: Sight, flow indicators            
               
Ends Finish: Diameters greater than or equal to 3/4" with lengths less than or equal to 72" are fire polished. All other  
diameters and lengths are saw cut.            
               
WARNING                
(1) Improper installation or maintenace of tublar glass can cause innediate or delayed glass breakage resulting in bodily injury. To avoid 
breakage observe the  Do's and Do Not's and Use and Care Instructions which are listed in the index, as well as tubular gage  
manufacturer's instructions.              
               
(2) If a gage glass breaks, contained substances can be released and glass can be blown out of the unit with great force. Always wear
safety glasses when looking toward a gage or working on a gage glass assembly. Guard against the possibility of fire and explosion.
               
(3) Protect glass from impact, scratches, other surface damage and sudden temperature changes. These can weaken or stress the glass
and lead to breakage.              
               
(4) A good safety practice is to incorporate a protective guard or shield in the gage glass assembly, i.e., a shield between the user
and the gage. Refer to the gage manufacturer's catalog.               
               
(5)Review in detail the Corrosives information which is listed in the index.        
               
(6) Review the disclaimer information which is listed in the index.        
               
(7) Clerical errors may exist in this chart. Please confirm information before relying on the data.    
               
                 Maximum Recommended
                 Working Pressure, psi
          Std.   Temperatures Steam Boiler
  Diameter Diameter   Wall Length Pcs. Per Up To 150 degrees F Service
Diameter Tolerances (+) Tolerances (-) Wall Tolerances (+/-) (Inches) * Case No Corrosion ** Up To 425 degrees F
1/2" O.D. 0.0"  -1/32"  5/64"  + / - 1/64" 8 12 460 340
(.500" O.D.) (.000") (.031") (.078") (+ / - .016") 10 12 445 335
          12 12 435 325
          14 12 415 315
* Intermediate lengths are available upon request. 16 12 400 300
  Maximum Length - 150"     18 12 385 295
          20 12 375 285
** See the Corrosives information cited in the index 24 12 340 270
          30 12 295 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 260 Not Recommended ***
          48 12 205 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 155 Not Recommended ***
          72 12 110 Not Recommended ***
5/8" O.D. 0.0"  -1/32"  3/32"  + / - 1/64" 8 12 435 320
(.625" O.D.) (.000") (.031") (.094") (+ / - .016") 10 12 420 315
          12 12 410 305
          14 12 390 295
* Intermediate lengths are available upon request. 16 12 375 285
  Maximum Length - 150"     18 12 360 280
          20 12 350 270
** See the Corrosives information cited in the index 24 12 320 255
          30 12 280 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 245 Not Recommended ***
          48 12 195 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 150 Not Recommended ***
          72 12 100 Not Recommended ***
3/4" O.D. 0.0"  -1/32"  7/64"  + / - 1/64" 8 12 425 315
(.750" O.D.) (.000") (.031") (.109") (+ / - .016") 10 12 410 310
          12 12 400 300
          14 12 385 290
* Intermediate lengths are available upon request. 16 12 370 280
  Maximum Length - 150"     18 12 355 275
          20 12 345 265
** See the Corrosives information cited in the index 24 12 315 250
          30 12 275 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 240 Not Recommended ***
          48 12 190 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 145 Not Recommended ***
          72 12 100 Not Recommended ***
7/8" O.D. 0.0"  -1/32"  1/8"  + / - 1/32" 8 12 380 Not Recommended ***
(.875" O.D.) (.000") (.031") (.125") (+ / - .031") 10 12 370 Not Recommended ***
          12 12 360 Not Recommended ***
          14 12 350 Not Recommended ***
* Intermediate lengths are available upon request. 16 12 340 Not Recommended ***
  Maximum Length - 150"     18 12 335 Not Recommended ***
          20 12 330 Not Recommended ***
** See the Corrosives information cited in the index 24 12 315 Not Recommended ***
          30 12 285 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 265 Not Recommended ***
          48 12 210 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 160 Not Recommended ***
          72 12 110 Not Recommended ***
1" O.D. 0.0"  -1/32"  1/8"  + / - 1/32" 8 12 345 Not Recommended ***
(1.000" O.D.) (.000") (.031") (.125") (+ / - .031") 10 12 335 Not Recommended ***
          12 12 325 Not Recommended ***
          14 12 320 Not Recommended ***
* Intermediate lengths are available upon request. 16 12 310 Not Recommended ***
  Maximum Length - 150"     18 12 305 Not Recommended ***
          20 12 300 Not Recommended ***
** See the Corrosives information cited in the index 24 12 285 Not Recommended ***
          30 12 260 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 240 Not Recommended ***
          48 12 190 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 145 Not Recommended ***
          72 12 110 Not Recommended ***
1 1/8" O.D. 0.0"  -3/64"  1/8"  + / - 1/32" 8 12 270 Not Recommended ***
(1.125" O.D.) (.000") (.047") (.125") (+ / - .031") 10 12 265 Not Recommended ***
          12 12 260 Not Recommended ***
          14 12 250 Not Recommended ***
* Intermediate lengths are available upon request. 16 12 245 Not Recommended ***
  Maximum Length - 150"     18 12 240 Not Recommended ***
          20 12 240 Not Recommended ***
** See the Corrosives information cited in the index 24 12 235 Not Recommended ***
          30 12 225 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 200 Not Recommended ***
          48 12 180 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 150 Not Recommended ***
          72 12 130 Not Recommended ***
1 1/4" O.D. 0.0"  -3/64"  1/8"  + / - 1/32" 8 12 240 Not Recommended ***
(1.250" O.D.) (.000") (.047") (.125") (+ / - .031") 10 12 235 Not Recommended ***
          12 12 230 Not Recommended ***
          14 12 225 Not Recommended ***
* Intermediate lengths are available upon request. 16 12 220 Not Recommended ***
  Maximum Length - 150"     18 12 215 Not Recommended ***
          20 12 215 Not Recommended ***
** See the Corrosives information cited in the index 24 12 210 Not Recommended ***
          30 12 200 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 180 Not Recommended ***
          48 12 160 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 135 Not Recommended ***
          72 12 115 Not Recommended ***
1 1/2" O.D. 0.0"  -3/64"  1/8"  + / - 1/32" 8 12 210 Not Recommended ***
(1.250" O.D.) (.000") (.047") (.125") (+ / - .031") 10 12 205 Not Recommended ***
          12 12 200 Not Recommended ***
          14 12 200 Not Recommended ***
* Intermediate lengths are available upon request. 16 12 195 Not Recommended ***
  Maximum Length - 150"     18 12 190 Not Recommended ***
          20 12 190 Not Recommended ***
** See the Corrosives information cited in the index 24 12 185 Not Recommended ***
          30 12 175 Not Recommended ***
*** Maximum length for steam boiler is 24"   36 12 160 Not Recommended ***
          48 12 140 Not Recommended ***
  Please review the Do's and Do Not's before installation.    60 12 120 Not Recommended ***
          72 12 100 Not Recommended ***
               
Sources: Corning Incorporated brochure "Tubular Gage Glasses"        